Input voltage: DC 12V
Receiving frequency: 433MHz, 315MHz (requires customer service)
Receive sensitivity: -108dbm
Working mode: jog, interlock, self-locking, two-way jog + two-way self-locking, two-way self-locking + two-way interlocking, two-way jog + two-way interlocking.(All modes are selected by the controller button)
Terminal block function description
1, (+V - positive input of power supply)
2, (GND - power supply negative input)
3, (1 - KC1 relay normally closed end) (2-KC1 relay common end) (3-KC1 relay normally open end)
4, (4-KC3 relay normally closed end) (5-KC3 relay common end) (6-KC3 relay normally open end)
5, (7-KC2 relay normally closed end) (8-KC2 relay common end) (9-KC2 relay normally open end)
6, (10-KC4 relay normally closed end) (11-KC4 relay common end) (12-KC4 relay normally open end)
Configuration method
Learn key=learn button
Clear code: Press the controller to learn the button 8 times (the first time you receive the product or need to change the working mode, you must clear the code).
Jog: Press the controller first, learn the button once, the LED light is on, then press the remote control of the code as needed, and the controller LED flashes three times and the configuration is completed.
Self-locking: first press the controller, learn the button 2 times, the LED light is on, then press the remote control of the code as needed, and the controller LED flashes three times, the configuration is completed.
Interlock: first press the controller, learn the button 3 times, the LED light is on, then press the remote control of the code as needed, the controller LED flashes three times